Born and raised Wisconsin techs · Authorized HACO Dealer

Machine down? Call (414) 381-0127

Born and raised Wisconsin techs · Authorized HACO Dealer

Machine down? Call (414) 381-0127

Motor and VFD · Wisconsin

Motor and VFD repair in Wisconsin

Motors and variable frequency drives that trip, overheat, growl or won’t start, diagnosed on site. Drive replacement and setup, motor testing, and the power quality problems behind repeat failures.

What we fix

Techs from the Milwaukee, Madison and Green Bay regions.

Quick answerLocalSpindle of Wisconsin troubleshoots and repairs industrial motors and VFDs across the state, including ABB, Allen-Bradley PowerFlex, Yaskawa, Siemens, Danfoss, Schneider Altivar, WEG, Baldor and Marathon. We find why drives trip and motors fail, replace and set up drives, test motors, and look at power quality and cooling so the fix lasts.

From our techs

Why drives trip

A drive that trips on overcurrent, overvoltage or overheating is usually reacting to something real: a motor with failing insulation, a load that binds, a decel time too short for the load, incoming power that sags or spikes, or a dirty heatsink. We read the fault history, measure the motor and power, and look at the load before we condemn the drive.

When a drive does need replacing, we install and set it up for the motor and the application, and save the parameters so the next replacement is quick.

Motors

Motors fail from bearings, heat and insulation breakdown. We test insulation and windings, check bearings by sound and vibration, and check alignment and belt tension. When a motor needs a rewind or replacement, we tell you which makes more sense.

Symptoms

What you're seeing, and what it usually means

The alarm names the axis or the unit. These are the causes we find behind it most often.

What you’re seeingWhat it usually means
Drive trips on overcurrentMotor or cable insulation, a binding load or acceleration set too fast.
Drive trips on overvoltage during stopDecel too fast or a missing braking resistor.
Drive overheatsDirty heatsink, failed fan or a hot panel.
Motor runs hotOverload, poor cooling, voltage imbalance or a failing winding.
Motor bearing noiseWorn bearings, misalignment or belt tension.
Repeated failures after stormsPower quality and surge protection.

How we work it

Motor and VFD: our approach

01

Read the history

What the drive saw before it tripped.

02

Measure

Motor, cable and power.

03

Fix or replace

With proper setup.

04

Save settings

So the next swap is fast.

A full visit

What a visit can cover

On the van

Example service call

Conveyor drive tripping on overvoltage every stop

The call

A distribution center in Kenosha County had a conveyor drive that tripped on overvoltage when the line stopped.

What we did

  1. Phone. We asked if the load had changed. It had: longer conveyor, heavier cartons.
  2. On site. The decel time was set for the old load and there was no braking resistor.
  3. Fix. Lengthened decel and added a braking resistor sized for the load.
  4. Check. Stopped the loaded line repeatedly without a trip.

The result. No more trips.

A typical call, written to show how we work. It isn’t a specific customer.

Talk to a Wisconsin tech

Same problem on your floor?

Call and a tech will tell you what we’d check first, then the closest team heads your way.

Brands

Motors, VFDs and power components we work on

Linked brands have their own page. See every brand we service.

From the field

Motor and VFD: tips from our techs

01

Save drive parameters

Keep a copy of settings for every drive.

02

Keep panels cool and clean

Heat is the top cause of drive failure.

03

Add surge protection

Rural and storm-prone areas see more power-related failures.

FAQ

Motor and VFD: questions

Still wondering? Call (414) 381-0127 and ask a tech.

ABB, Allen-Bradley PowerFlex, Yaskawa, Siemens, Danfoss, Schneider Altivar, Mitsubishi, Fuji, Hitachi, Lenze and others.

Yes, and set it up for your motor and application.

Yes, insulation, windings and bearings.

We arrange rewinds or replacement and tell you which makes sense.

We check voltage, balance and grounding and recommend fixes.

Who comes out

Wisconsin teams for motor and vfd

The founding team closest to your shop takes the call. Central and western Wisconsin calls go to whichever team is nearest.

Milwaukee

Southeast Wisconsin. Motor and vfd calls in Milwaukee, Waukesha, New Berlin, Menomonee Falls, Germantown, West Allis and nearby towns.

Madison

South central Wisconsin. Motor and vfd calls in Madison, Sun Prairie, Middleton, Janesville, Beloit, Watertown and nearby towns.

Green Bay

Northeast Wisconsin and the Fox Valley. Motor and vfd calls in Green Bay, De Pere, Appleton, Neenah and Menasha, Oshkosh, Fond du Lac and nearby towns.

Keep reading

Related repair

Machine down?

Get your motor and vfd sorted

Call and talk to a tech about the machine, the control and the symptom. The Wisconsin team closest to you takes it from there.